Rev. cuba. pediatr ; 92(3): e752, jul.-set. 2020. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1126773

ABSTRACT

Introducción: La colocación de stents mediante cateterismo cardiaco en recién nacidos con ciertas cardiopatías congénitas complejas constituye un puente hacia la cirugía correctiva, paliativa o trasplante cardiaco. Objetivo: Evaluar el resultado del implante percutáneo de stents en pacientes recién nacidos con cardiopatías congénitas complejas. Presentación de los casos: Se colocó stents en cinco pacientes; a uno de ellos en la aorta y a los cuatros restantes en el ductus arterioso. Un primer paciente con hipoplasia de cavidades izquierdas en el que predominaba el bajo gasto se le colocó stent en el ductus e inmediatamente se le condujo al salón de operaciones para cerclaje pulmonar. Otro paciente con la misma enfermedad, pero en el que predominaba el hiperflujo pulmonar, se intervino de forma inversa, medió 47 días entre uno y otro proceder. A un tercer paciente, portador de coartación aórtica, se le colocó stent en la aorta y se le hizo cerclaje pulmonar 14 días después del proceder hemodinámico. Las condiciones clínicas del cuarto paciente, con síndrome de hipoplasia de cavidades izquierdas solo permitió colocar stent en el ductus. Esta paciente fallece en evento no relacionado con el cateterismo cardiaco. El último paciente intervenido, portador de una atresia pulmonar, tolera la colocación del stent en el ductus y la evolución clínica posterior demostró que no requería realizar cerclaje pulmonar. Conclusiones: La colocación de stent en el grupo de pacientes analizado es factible y el momento de su implante según el evento hemodinámico apremiante pudiera ser una forma alternativa del cateterismo cardiaco(AU)


Introduction: The paliative placing of stents by cardiac catetherism in new borns with specific congenital hearts diseases is a bridge through a new kind of corrective, paliative surgery or heart transplant. Objective: To evaluate the result of the percutaneous implant of stents in newborn patients with complex congenital heart diseases. Cases presentation: There were placed stents in 5 patients, to one of them in the aorta and to the other four in the ductus arteriosus. The first patient with hypoplasia of the left cavities in which low output predominated had an stent placing in the ductus and he was immediately taken to OR to perform a pulmonary cerclage. Another patients with the same disease but with predominance of pulmonary hyperflow was intervened in the inverse way; there were 47 days between both procedures. A third patient, carrier of aortic coarctation, had an stent placing in the aorta and he also had pulmonary cerclage 14 days after the hemodynamic procedure. The clinical conditions of the fourth patient, who had syndrome of left cavities´ hypoplasia, just allowed to place the stent in the ductus. This patients died in a procedure not related to heart catetherism. The last intervened patient, who was a carrier of pulmonary atresia, tolerated the stent placing in the ductus and the subsequent clinical evolution showed that it was not needed pulmonary cerclage. Conclusions: The stent placing in the analized group of patients is suitable and the moment for its implantation according to the hemodynamic event can be an alternative form of heart catetherism(AU)


Subject(s)
Humans , Male , Female , Infant, Newborn , Cardiac Catheterization/methods , Stents/standards , Heart Defects, Congenital/surgery
2.
Rev. cuba. pediatr ; 92(1): e783, ene.-mar. 2020. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1093746

ABSTRACT

Introducción: El cateterismo intervencionista corrige las cardiopatías complejas, donde el dispositivo Amplatzer es el más usado y está disponible en Cuba. Objetivo: Evaluar el cateterismo intervencionista con Amplatzer, en el cierre de la comunicación interauricular ostium secundum. Métodos: Estudio de evaluación, longitudinal y prospectivo en 92 pacientes. El cierre de la comunicación por cateterismo con Amplatzer, se realizó en el Cardiocentro Pediátrico William Soler (2010-2016). Se utilizaron variables demográficas, ecocardiográficas (transtorácicas y transesofágicas) antes, durante y al año del cateterismo. Se observaron las complicaciones. La evaluación clínica y ecocardiográfica se realizó al año poscateterismo. Los pacientes a quienes se les realizó el proceder en el 2016, se evaluaron a los 6 meses. Resultados: Se encontraron diferencias significativas en el sexo (p<0,05): femenino 64,1 por ciento con homogeneidad para la edad (p= 0,244): media 9,8 años ( 5 desviaciones estándar. Precateterismo: 28,3 por ciento eran desnutridos y 17,4 por ciento delgados; poscateterismo la desnutrición mejoró significativamente (p= 0,000): desnutridos 9,8 por ciento y delgados 8,7 por ciento. El diámetro medio del defecto por ecocardiografía transcateterismo fue significativo (p= 0,000). Transcateterismo: 98,9 por ciento con cierre de defecto, 16,3 por ciento con insuficiencia tricúspidea y 4,3 por ciento con insuficiencia mitral. Poscateterismo: 98,9 por ciento con Amplatzer bien colocado. Hubo complicaciones inmediatas en 8,7 por ciento (arritmias, derrame pericárdico y embolización). Al año se detectó cortocircuito residual pequeño (n= 1) e insuficiencias valvulares auriculoventriculares (n= 3). La evolución fue satisfactoria (n= 91). Conclusiones: La evolución del cierre de la comunicación interauricular ostium secundum con dispositivo Amplatzer es satisfactoria, con mejoras de la desnutrición(AU)


Introduction: The interventional catheterization corrects complex heart diseases, and the Amplatzer device is the most widely used and is available in Cuba. Objective: To assess the interventional catheterization with Amplatzer device in the ostium secundum atrial septal closure. Methods: Longitudinal and prospective evaluation study in 92 patients. The closure of the communication by Amplatzer catheterization was performed in the William Soler Pediatric Cardiocenter of (2010-2016). Demographic and echocardiographic (transthoracic and transesophageal) variables were used before, during, and at the year of the catheterization. Complications were observed. Clinical and echocardiographic assessment was made a year after catheterism. The patients who underwent the procedure in 2016 were evaluated at 6 months. Results: Significant differences were found in the sex (p< 0.05): Female 64.1 t percent with homogeneity of the age (p= 0.244): average 9.8 years ( 5 standard deviations. Pre-catheterism: 28.3 percent were malnourished and 17.4 percent thin; post-catheterism: malnutrition improved significantly (p= 0.000): 9.8 percent malnourished and 8.7 percent thin. The average diameter of the defect by transcatheter echocardiography was significant (p= 0.000). Transcatheter: 98.9 percent : with default closure, 16.3 percent with tricuspid insufficiency and 4.3 percent with mitral regurgitation. Post-catheterism: 98.9 percent with Amplatzer device correctly positioned. There were immediate complications in 8.7 percent (arrhythmia, pericardial effusion, and embolization). A year after, small residual short circuit was detected (n= 1), and atrioventricular valve regurgitation (n= 3). The evolution was satisfactory (n= 91). Conclusions: The evolution of ostium secundum atrial septal defect´s closure with Amplatzer device is satisfactory and improves malnutrition(AU)


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Cardiac Catheterization/methods , Atrial Septum/physiopathology , Septal Occluder Device/standards , Prospective Studies , Longitudinal Studies
3.
Rev. cuba. pediatr ; 84(3): 301-306, jul.-set. 2012.
Article in Spanish | LILACS | ID: lil-650778

ABSTRACT

La estenosis pulmonar valvular crítica es una cardiopatía congénita relativamente frecuente en el recién nacido, cuya supervivencia depende de una intervención inmediata, ya sea farmacológica o quirúrgica. Su diagnóstico prenatal ha permitido tratarla in útero mediante dilatación de la válvula por angioplastia con balón. Esta técnica conlleva los riesgos inherentes a todo proceder que implique el acceso al feto. Está demostrado que con la angioplastia posnatal precozmente diagnosticada mediante ecocardiografía, se pueden obtener resultados igualmente satisfactorios, previa estabilización clínica y hemodinámica del paciente. Apostamos, pues, por esta última.


Critical valvular pulmonary stenosis is a relatively frequent congenital cardiopathy in the newborn, whose survival depends on an immediate intervention either pharmacological or surgical. The prenatal diagnosis allows the intrauterine treatment by dilating the valve through the ball angioplasty. This technique carries the risks inherent to any procedures involving access to the fetus. It has been proved that postnatal angioplasty, early diagnosed with echography, can obtain the same satisfactory results, after the clinical and hemodynamic stabilization of the patient. Therefore, we support postnatal angioplasty.

4.
Rev. cuba. pediatr ; 83(2): 182-187, abr.-jun. 2011.
Article in Spanish | LILACS | ID: lil-615676

ABSTRACT

Se documenta el caso de un paciente de 1 mes de edad, prematuro, con peso de 1 600 g, cuyo catéter epicutáneo se fracturó y desplazó hasta ubicarse en la porción distal en la rama izquierda de la arteria pulmonar. El catéter se extrajo por vía femoral mediante un procedimiento de cateterismo cardíaco intervencionista, con lo que se demostró la efectividad de dicho procedimiento ante este tipo de complicación


This is the case of a premature patient aged one month weighing 1 600 g, whose epicutaneous catheter was fractured moving to be located in the distal portion in the left branch of pulmonary artery. The catheter was removed by femoral route by interventionist cardiac catheterization allowing us to demonstrate the effectiveness of such procedure in this type of complication

5.
Rev. cuba. pediatr ; 78(2)abr.-jun. 2006. ilus
Article in Spanish | LILACS | ID: lil-465289

ABSTRACT

Se realizó un estudio retrospectivo de 36 pacientes con comunicación interauricular significativa, a quienes se realizó un cierre percutáneo del defecto mediante un dispositivo Amplatzer. El objetivo del trabajo fue evaluar la factibilidad y seguridad del proceder en nuestro medio. Se concluyó que el método empleado es una atractiva alternativa para el tratamiento quirúrgico


Subject(s)
Cardiac Catheterization/methods , Heart Septal Defects, Atrial
6.
Rev. cuba. pediatr ; 78(2)abr.-jun. 2006. ilus, graf
Article in Spanish | LILACS | ID: lil-465291

ABSTRACT

Se realiza un análisis retrospectivo de 36 pacientes con cierre de comunicación interauricular, con el objetivo de evaluar la utilidad de la ecocardiografía transesofágica durante este proceder. Se describen las vistas ecocardiográficas utilizadas, así como se determina mediante ecuaciones de regresión la relación entre las dimensiones de la comunicación interauricular por ecocardiografía transtorácica, ecocardiografía transesofágica y después del balón distendido. Se concluye que las vistas de ecocardiografía transesofágica utilizadas en nuestro trabajo permiten el cierre satisfactorio de la comunicación interauricular mediante dispositivo Amplatzer y que la dimensión de la comunicación interauricular después del balón distendido puede ser estimada a partir de las ecocardiografías transesofágica y transtorácica


Subject(s)
Echocardiography, Transesophageal/methods , Heart Septal Defects, Atrial